FLUKE

Sort By:  
The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals.
$1,200.00
The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.
$2,500.00
The DSX CableAnalyzer accelerates every step of the certification process thanks to its modular design which supports copper certification, fibre optic loss, OTDR testing and fibre end-face inspection, it's unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards and Fluke Networks ProjX system which helps to manage job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly.
$6,000.00
USED FLUKE 726 PRECISION MULTIFUNCTION PROCESS CALIBRATOR SALE!! (FLUKE 726 PRECISION MULTIFUNCTION PROCESS CALIBRATOR)

Measurement Capabilities
This precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and/or sources pressure using when paired with any of the 50 Fluke 750P series Pressure Modules to test and calibrate pressure transmitters and other devices. The 726 can also:

  • Source mA with simultaneous pressure measurement to conduct valve and I/P test
  • Conduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode

Designed For Ease Of Use
The 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.

You can also use the 726 to:

  • Capture the set, reset, and deadband of a pressure switch with the integrated switch test
  • Calculate the transmitter error % to interpret calibration results without the use of a calculator
  • Perform fast linearity tests with the auto-step and auto-ramp features
  • Power a transmitter during test using 24 V loop supply and simultaneous mA measurement

 

Features:

  • More precise measurement and calibration source performance, accuracies of 0.01%.
  • Two separate channels; measure, source and view process signals simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters
  • Measure or source pressure* using any of 29 Fluke 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Integrated pressure switch test allows you to capture the set, reset and deadband of a switch
  • Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis
  • Transmitter error% calculation, interpret calibration results without a calculator
  • Perform fast linearity tests with auto step and auto ramp features
  • Power transmitters during test using 24 V loop supply and simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing
  • HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation
  • Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement.
  • New voltage input protection design for improved reliability

Fluke 726 Specifications
Measurement Accuracy
Voltage DC30.000 V0.01% 2 mV (upper display).
20.000 V0.01% 2 mV (lower display).
90.00 mV0.01% 10 μV.
-10.00 mV to 75.00 mV0.025% 1 count (via TC connector).
Current DC24.000 mA0.01% 2 mA.
Resistance0.0 to 4000.0 Ω± 0.015%.
Frequency2.0 to 1000.0 CPM0.05% 0.1 cpm.
1.0 to 1000.0 Hz0.05% 0.1 Hz.
1.00 to 15.00 kHz0.05% 0.01 kHz.
Sensitivity1 V peak-to-peak-minimum.
Pressure

Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.

Source Accuracy
Voltage DC100.00 mV0.01% 10 μV.
20.000 V0.01% 2 mV.
-10.00 mV to 75.00 mV0.025% 1 count (via TC connector).
Current DC24.000 mA (Source)0.01% 2 μA.
24.000 mA (Simulate)0.01% 2 μA.
ResistanceRange, accuracy (percent of reading floor) and excitation current5 to 400 Ω, 0.015% 0.1 Ω, 0.1 to 0.5 mA.
5 to 400 Ω, 0.015% 0.05 Ω, 0.5 to 3 mA.
400 to 1500 Ω, 0.015% 0.5 Ω, 0.05 to 0.8 mA.
1500 to 4000 Ω, 0.015% 0.5 Ω, 0.05 to 0.4 mA.
Frequency2.0 to 1000.0 CPM0.05%.
1.0 to 1000.0 Hz0.05%.
1.0 to 10.0 kHz0.25%.
10.0 to 15.0 kHz0.5%.
Waveform5 V p-p squarewave, -0.1 V offset.
RTDs and Thermocouples
Measure and source accuracyCu101.8°C.
NI-1200.15°C.
PT-100 (385)0.45°C.
PT-100 (392)0.35°C.
PT-100 (391-JIS)0.35°C.
PT-200 (385)0.95°C.
PT-500 (385)0.55°C.
PT-1000 (385)0.35°C.
RTD Resolution0.01°C (0.01°F).
Cu10.01 C0.1°C (0.1°F).
J0.4°C.
K0.5°C.
T0.4°C.
E0.4°C.
R1.4°C.
S1.4°C.
B1.4°C.
L0.45°C.
U0.45°C.
N0.6°C.
XK0.4°C.
BP1.1°C.
TC ResolutionJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F.
Specifications
Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature.
RampsSlow ramp, Fast ramp, 25% step-ramp.
Loop power functionVoltage24 V.
Accuracy10%.
Maximum current22 mA, short circuit protected.
Step functionsSource functionsVoltage, current, resistance, frequency, temperature.
Steps25% of range, 100% of range.
Environmental Specifications
Operating temperature-10°C to 55°C.
Storage temperature-20°C to 71°C.
Operating altitude3000 m.
Safety Specifications
Agency approvalsEN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992.
Mechanical and General Specifications
Size200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in).
Weight650 g (23 oz).
Batteries4 AA alkaline batteries.
Battery replacementSeparate battery compartment, accessible without breaking calibration seal.
Side port connectionsPressure module connector, also used for remote real-time programming.
The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals.
$1,200.00
NEW FLUKE 726 PRECISION MULTIFUNCTION PROCESS CALIBRATOR SALE!! (FLUKE 726 PRECISION MULTIFUNCTION PROCESS CALIBRATOR)

Measurement Capabilities
This precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and/or sources pressure using when paired with any of the 50 Fluke 750P series Pressure Modules to test and calibrate pressure transmitters and other devices. The 726 can also:

  • Source mA with simultaneous pressure measurement to conduct valve and I/P test
  • Conduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode

Designed For Ease Of Use
The 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.

You can also use the 726 to:

  • Capture the set, reset, and deadband of a pressure switch with the integrated switch test
  • Calculate the transmitter error % to interpret calibration results without the use of a calculator
  • Perform fast linearity tests with the auto-step and auto-ramp features
  • Power a transmitter during test using 24 V loop supply and simultaneous mA measurement

 

Features:

  • More precise measurement and calibration source performance, accuracies of 0.01%.
  • Two separate channels; measure, source and view process signals simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters
  • Measure or source pressure* using any of 29 Fluke 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Integrated pressure switch test allows you to capture the set, reset and deadband of a switch
  • Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis
  • Transmitter error% calculation, interpret calibration results without a calculator
  • Perform fast linearity tests with auto step and auto ramp features
  • Power transmitters during test using 24 V loop supply and simultaneous mA measurement
  • Store frequently-used test setups for later use
  • Frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing
  • HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation
  • Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement.
  • New voltage input protection design for improved reliability

Fluke 726 Specifications
Measurement Accuracy
Voltage DC30.000 V0.01% 2 mV (upper display).
20.000 V0.01% 2 mV (lower display).
90.00 mV0.01% 10 μV.
-10.00 mV to 75.00 mV0.025% 1 count (via TC connector).
Current DC24.000 mA0.01% 2 mA.
Resistance0.0 to 4000.0 Ω± 0.015%.
Frequency2.0 to 1000.0 CPM0.05% 0.1 cpm.
1.0 to 1000.0 Hz0.05% 0.1 Hz.
1.00 to 15.00 kHz0.05% 0.01 kHz.
Sensitivity1 V peak-to-peak-minimum.
Pressure

Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.

Source Accuracy
Voltage DC100.00 mV0.01% 10 μV.
20.000 V0.01% 2 mV.
-10.00 mV to 75.00 mV0.025% 1 count (via TC connector).
Current DC24.000 mA (Source)0.01% 2 μA.
24.000 mA (Simulate)0.01% 2 μA.
ResistanceRange, accuracy (percent of reading floor) and excitation current5 to 400 Ω, 0.015% 0.1 Ω, 0.1 to 0.5 mA.
5 to 400 Ω, 0.015% 0.05 Ω, 0.5 to 3 mA.
400 to 1500 Ω, 0.015% 0.5 Ω, 0.05 to 0.8 mA.
1500 to 4000 Ω, 0.015% 0.5 Ω, 0.05 to 0.4 mA.
Frequency2.0 to 1000.0 CPM0.05%.
1.0 to 1000.0 Hz0.05%.
1.0 to 10.0 kHz0.25%.
10.0 to 15.0 kHz0.5%.
Waveform5 V p-p squarewave, -0.1 V offset.
RTDs and Thermocouples
Measure and source accuracyCu101.8°C.
NI-1200.15°C.
PT-100 (385)0.45°C.
PT-100 (392)0.35°C.
PT-100 (391-JIS)0.35°C.
PT-200 (385)0.95°C.
PT-500 (385)0.55°C.
PT-1000 (385)0.35°C.
RTD Resolution0.01°C (0.01°F).
Cu10.01 C0.1°C (0.1°F).
J0.4°C.
K0.5°C.
T0.4°C.
E0.4°C.
R1.4°C.
S1.4°C.
B1.4°C.
L0.45°C.
U0.45°C.
N0.6°C.
XK0.4°C.
BP1.1°C.
TC ResolutionJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F.
Specifications
Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature.
RampsSlow ramp, Fast ramp, 25% step-ramp.
Loop power functionVoltage24 V.
Accuracy10%.
Maximum current22 mA, short circuit protected.
Step functionsSource functionsVoltage, current, resistance, frequency, temperature.
Steps25% of range, 100% of range.
Environmental Specifications
Operating temperature-10°C to 55°C.
Storage temperature-20°C to 71°C.
Operating altitude3000 m.
Safety Specifications
Agency approvalsEN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992.
Mechanical and General Specifications
Size200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in).
Weight650 g (23 oz).
Batteries4 AA alkaline batteries.
Battery replacementSeparate battery compartment, accessible without breaking calibration seal.
Side port connectionsPressure module connector, also used for remote real-time programming.
The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.
$2,500.00
NEW FLUKE NETWORKS DSX2-8000QOI SALE!! (FLUKE NETWORKS DSX2-8000QOI)

The Fluke Networks DSX CableAnalyzer series copper cable certifiers enable measurement and certification of twisted pair cabling up to 40 Gigabit Ethernet and can be used for all cabling systems such as Cat 5e, 6, 6A, 8 or class FA and I / II. Cabling certification is part of a process that begins with system design and ends with the system warranty. The faster this process is completed, the faster the investment pays off. Unfortunately, there are many factors that slow down the process. Incorrect configuration of the meter, testing the wrong limits, waiting for experienced technicians to analyze or correct problems, misinterpreting the results and reports that customers cannot understand are just a few examples.

The copper cable certifiers of the DSX CableAnalyzer series are part of the Versiv product family for copper cable certification, which offers precise and error-free cabling certification. Several teams, different media types and several test requirements are involved in the installation. When it comes to profitability, often only a few percentage points are the tip of the scales. DSX certified copper cabling is compliant with all standards, including accuracy level VI / 2G, makes it easier to manage orders and leads to a faster system guarantee. The solution is not only aimed at experienced technicians and project managers. People with different skills can improve setup, operation and test reports while managing different projects.

The DSX2-8000-QOI CableAnalyzer copper test solution with the CertiFiber Pro Quad OLTS module and the OptiFiber Pro Quad OTDR module enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv 2 cabling certification product family, the DSX CableAnalyzer provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects. The DSX2-8000-QOI also includes integrated WiFi functionality for connecting wirelessly to Fluke Network's LinkWare Live.

Features:

  • The modular Versiv design supports copper certification, fiber optic attenuation, OTDR tests and testing of the fiber end faces.
  • Unrivaled speed level for Cat 6A, 8, Class FA and all current standards
  • The ProjX system manages task requirements and progress from setup to system acceptance to ensure that all tests are completed.
  • The Taptive user interface simplifies setup and eliminates errors.
  • Analyze test results and create professional test reports using LinkWare management software.
  • Graphic display of error sources (e.g. crosstalk, return loss and shielding errors) for even faster diagnosis.
  • Intertek verified to TIA Level 2G - the strictest accuracy requirements.
  • Our copper cable certification tools are supported by cabling companies worldwide.
  • Integrated alien crosstalk tests.
  • Compatible with Linkware Live.

Come With:

  • One (1) Versiv Mainframe & Remote
  • Two (2) DSX-8000 CableAnalyzer modules
  • Two (2) CertiFiber Quad OLTS modules
  • One (1) OptiFiber Quad OTDR module
  • One (1) Set of Cat 8/Class I Permanent Link Adapters
  • One (1) Set of Cat 8/Class 1 Channel Adapters
  • Two (2) Headsets
  • Two (2) HandStraps
  • Two (2) Shoulder Straps
  • One (1) Hard sided Carry Case
  • One (1) USB Interface Cable
  • One (1) Versiv 2 Open Source Software CD
  • Two (2) AC Chargers
  • Two (2) Universal Couplers
  • Two (2) AxTalk Terminators
  • Two (2) Quick Clean Cleaners (1.25/2.50 mm)
  • One (1)SC/SC Simplex adapters
  • Two (2) SC/LC Multimode Launch Cables-50 µm
  • Two (2) SC/LC Singlemode Launch Cable-9 µm
  • One (1) USB Fiber Inspection Video Probe with 4 Tips
  • Two (2) LC/LC Simplex Adapter
  • One (1) SC/LC EF-Compliant MM TRC Kit 50 µm
  • One (1) SC/LC SM TRC Kit
  • One (1) TRC Carry Case
  • One (1) WiFi Adapter for Versiv 2 Mainframe
  • One (1) Statement of Calibration
  • One (1) Start Guide
The DSX CableAnalyzer accelerates every step of the certification process thanks to its modular design which supports copper certification, fibre optic loss, OTDR testing and fibre end-face inspection, it's unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards and Fluke Networks ProjX system which helps to manage job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly.
$6,000.00
Per Page      1 - 5 of 5
  • 1